Parameter |
Specifications |
Input Voltage Range |
... 24V ... (Range 18-36V) |
|
... 48V ... (Range 36-75V) |
Positive Logic Remote On/Off |
see note 3 & 4 |
Input Filter |
Pi Type |
Voltage Accuracy |
±1% max |
Transient Response |
... 25% step load ... < 500 μ sec |
External Trim Adj. Range |
±10% |
R&N (20MHz BW) |
... 2.5, 3.3 & 5 ... 100mVp-p max |
|
... 12V & 15V ... 150mVp-p max |
|
... 24V ... 240mVp-p max |
Temperature Coefficient |
±0.03% / °C max |
Short Circuit Protection |
Continuous |
Line Regulation ¹ |
±0.2% max |
Load Regulation ² |
±0.2% max |
O.V.P. Trip Range, % Vo nom |
115~140% |
Current Limit |
110~140% Nominal Output |
Efficiency |
See Model List |
Isolation Voltage |
1500VDC |
Switching Frequency |
500KHz, Typ. |
Isolation Resistance |
10M Ω min |
Operating Case Temperature |
-40°C to 100°C |
Storage Temperature |
-40°C to 105°C |
Thermal Shutdown, Case Temp. |
100°C Typ. |
Case Material |
Aluminum |